Series -C- Product Cooler
• Superfin™ Construction
• Hot Gas, Air or Electric Defrost **
• UL Recognized
• CRN Recognized

Cabinets

Attractive cabinets are constructed of heavy gauge galvanized sheet metal which virtually eliminates rust and corrosion. galvanized structural supports are provided to prevent panel vibration. units are completely factory assembled and shipped upright ready for field installation. An optional platform mount is available for all models. Brackets are provided on top of all models.

Coils

All units with 7/8" O.D. tube are furnished with MCC's Superfin™ construction. This equilateral pattern, staggered tube design is the ultimate in extended surface heat transfer. Featuring fully drawn collars in 2 through 14 FPI spacing, the fins are self spacing and mechanically bonded to the tubes. This design was heavily influenced by those used in ARI listed coils with changes to suit low temperature conditions. Variable fin spacing is available in multiples of the widest spacing (i.e., 1.5/3/6 or 2/4/8). These coils are available in copper or aluminum tube versions for halocarbon refrigerants or aluminum tube for ammonia refrigerant. Coils are also available with a corrosion resistant coating for use in harsh environments.

Motors

Direct drive AMCA rated axial fans are provided. All fans and motors are modular and can be interchanged between unit sizes. OSHA style fan guards are on all models. Motors are ball bearing, TEAO.

Drain Pan

Rapid removal of condensate is accomplished by the use of a full sized (mounted as standard) drain pan. Drain pans can be insulated when required.

Hot Gas Coils

All models are available with hot gas defrost applications. The hot gas coil is provided with a check valve between the hot gas pan coil and the inlet to the evaporator coil as standard. All hot gas defrost units feature the "No Bridge" crossover system*.

* US Patent #5315836
** Electric defrost not UL recognized

Top


Series -CF- Product Coolers

 

Information Coming Soon.

 

 

Top


Series -D- Product Coolers
• Low Velocity Dual Coils For Coolers
• High Velocity Dual Coils For freezers
• 80 Models
• Superfin™ Construction
• 12 to 75 sq. ft. Face Area
• 6,300 to 46,500 CFM
• 3.3 to 32 Tons (at 10° temp difference)
• Hot Gas or Air Defrost
• UL Recognized
• CRN Recognized

Cabinets

Modular, heavy duty, mill galvanized, sheet steel construction to eliminate rust and corrosion. Panels are formed with strategically placed flanges to prevent excessive panel flutter. Hangers are bolted to internal structural pieces to ensure total support of the unit. Units are shipped completely factory assembled in the upright position and are ready for rigging.

Expansion Valves

All direct expansion coils are available with factory selected and mounted thermal expansion valves.

Coils

All units with 7/8" O.D. tube are furnished with MCC's "Superfin™" construction. This equilateral pattern, staggered tube design is the ultimate in extended surface heat transfer. Featuring fully drawn collars in 2 through 14 FPI spacing, the fins are self spacing and mechanically bonded to the tubes. This design was heavily influenced by those used in ARI listed coils with changes to suit low temperature conditions. Variable fin spacing is available in multiples of the widest spacing (i.e., 1.5/3/6 or 2/4/8). These coils are available in copper or aluminum tube versions for halocarbon refrigerants or aluminum tube for ammonia refrigerant. Coils are also available with a corrosion resistant coating for use in harsh environments.

Motors

All motors are totally enclosed to minimize the possibility of winding contamination from moisture and airborne materials. All motors are mounted on a galvanized formed steel plate base. 50HZ motors are available for all applications. All Motors are prewired to a junction box.

Fans

Direct drive axial fans are a heavy duty industrial design All are mill galvanized steel construction for corrosion resistance. All fans are shrouded by a computer designed volute for maximum efficiency. All fans are compartmentalized.

Drain Pan

Rapid removal of condensate is accomplished by the use of sloped drain pans. The pans can be furnished with an insulated bottoms where required Insulated pans are suggested when using hot gas defrost and/or when the unit is located in an area with high humidity.

Hot Gas Coils

All models are available with hot gas defrost. The hot gas pan coils are furnished with a mounted and prepiped check valve between the pan coils and the evaporator coils as standard. Units with hot gas defrost in the coil only do not have the pan coil and check valve (the defrost piping is external to the unit and done by others). All hot gas defrost units feature the "no bridge" crossover system*

* US Patent #5315836

Top


Series -L- Unit Coolers
• 54 Models
• Superfin™ Construction
• 5,326 to 10,652 CFM
• 3.0 to 10.6 tons (at 10° temp difference)
• Hot Gas, Air or Electric Defrost
• UL Recognized
• CRN Recognized

Cabinets

Attractive cabinets are constructed of heavy gauge galvanized sheet metal which virtually eliminates rust and corrosion. galvanized structurals supports are provided to prevent panel vibration. units are completely factory assembled and shipped upright ready for field installation. An optional platform mount is available for all models. Brackets are provided on top of all models.

Coils

All units with 7/8" O.D. tube are furnished with MCC's Superfin™ construction. This equilateral pattern, staggered tube design is the ultimate in extended surface heat transfer. Featuring fully drawn collars in 2 through 14 FPI spacing, the fins are self spacing and mechanically bonded to the tubes. This design was heavily influenced by those used in ARI listed coils with changes to suit low temperature conditions. Variable fin spacing is available in multiples of the widest spacing (i.e., 1.5/3/6 or 2/4/8). These coils are available in copper or aluminum tube versions for halocarbon refrigerants or aluminum tube for ammonia refrigerant. Coils are also available with a corrosion resistant coating for use in harsh environments.

Motors

Direct drive AMCA rated axial fans are provided. All fans and motors are modular and can be interchanged between unit sizes. OSHA style fan guards are on all models. Motors are ball bearing, TEAO.

Drain Pan

Rapid removal of condensate is accomplished by the use of a full sized (mounted as standard) drain pan. Drain pans can be insulated when required.

Hot Gas Coils

All models are available with hot gas defrost applications. The hot gas coil is provided with a check valve between the hot gas pan coil and the inlet to the evaporator coil as standard. All hot gas defrost units feature the "No Bridge" crossover system*.

* US Patent #5315836

Top

Series -M- Product Coolers
• Superfin™ Construction
• 8 to 117 sq. ft. Face Are
• 4,600 to 117,000 CFM
• 1.7 to 91.3 Tons (at 10° temp difference)
• Hot Gas, Air, Water or Electric Defrost
• UL Recognized
• CRN Recognized

Construction

Coils

All units with 7/8" O.D. tube are furnished with MCC's Superfin™ construction. This equilateral pattern, staggered tube design is the ultimate in extended surface heat transfer. Featuring fully drawn collars in 2 through 14 FPI spacing, the fins are self spacing and mechanically bonded to the tubes. This design was heavily influenced by those used in ARI listed coils with changes to suit low temperature conditions. Variable fin spacing is available in multiples of the widest spacing (i.e., 1.5/3/6 or 2/4/8). These coils are available in copper or aluminum tube versions for halocarbon refrigerants or aluminum tube for ammonia refrigerant. Coils are also available with a corrosion resistant coating for use in harsh environments.

Cabinets

Modular, heavy duty, mill galvanized, sheet steel construction to eliminate rust and corrosion. Panels are formed with strategically placed flanges to prevent excessive panel flutter. Hangers are bolted to internal structural pieces to ensure total support of the unit. Units are shipped completely factory assembled in the upright position and are ready for rigging.

Expansion Valves

All direct expansion coils are available with factory selected and mounted thermal expansion valves.

Drain Pan

Rapid removal of condensate is accomplished by the use of a full sized (mounted as standard) drain pan. Drain pans can be insulated when required.

Motors

All motors are totally enclosed to minimize the possibility of winding contamination from moisture and airborne materials. All motors are mounted on a galvanized formed steel bases. The modular design of this assembly allows limited changes in horsepower/RPM/fan combinations within the parameters of the M Series catalogue. 50 HZ motors are available for all applications. All Motors are prewired to junction boxes.

Fans

Direct drive axial fans are a heavy duty industrial design All are mill galvanized steel construction for corrosion resistance. Cast aluminum fans are available for specific applications. All fans are shrouded by a computer designed volute for maximum efficiency. All fans are compartmentalized.

Hot Gas Pan Coils

All models are available with hot gas defrost. The hot gas pan coil is furnished with a mounted and prepiped check valve between the pan coil and the evaporator coil as standard. Units with hot gas defrost in the coil only do not have the pan coil and check valve (the defrost piping is external to the unit and done by others). All hot gas defrost units feature the "no bridge" crossover system*.

Electric Defrost

Electric defrost** is available on all units. The defrost heater elements are low watt density, large diameter stainless steel sheathed elements inserted directly into the coil fins. The fins have a drawn collar similar to the tube hole. The heaters are held in place by a clip to prevent them from creeping. The heaters have molded silicone rubber leads and are UL listed. All wiring is terminated in a junction box including a termination 'stat for easy field connection.
 
* US Patent #5315836
** Electric Defrost units not UL recognized

Optional Features

45° Fan Turndowns

Constructed of heavy gauge galvanized sheet and mounted to the front of the unit cabinet, these help direct the air for certain types of blast freezing operations.

90° Fan Turndowns

Constructed of heavy gauge galvanized sheet and mounted to the front of the unit cabinet, these allow the standard evaporator to be used in penthouse applications.

Extended Legs

Constructed of structural steel (hot dipped galvanized) and heavy gauge galvanized sheet, these raise the evaporator for penthouse applications and certain other platform mounted requirements.

Motors

Two speed, high efficiency, or exposion proof motors are available on all unit sizes.

Long Throw Nozzles

Tapered long throw nozzles are available to enhance the air flow. The units with 26" fans normally throw approximately 80', 36" fans approximately 115' and 42" fans approximately 140'. The addition of the long throw nozzle adds an estimated 30% to the throw.

Top


Series -R- Rail Riders
• Superfin™ Construction
• 48 Models
• 5.9 to 27.5 Tons (at 10° temperature difference)
• Hot Gas, Air or Electric Defrost*
• UL Recognized
• CRN Recognized

Cabinets

Attractive cabinets are constructed of heavy gauge galvanized sheet metal which vertually eliminates rust and corrosion. galvanized structurals supports are provided to prevent panel vibration. units are completely factory assembled and shipped upright ready for field installation.

Coils

All units with 7/8" O.D. tube are furnished with MCC's Superfin™ construction. This equilateral pattern, staggered tube design is the ultimate in extended surface heat transfer. Featuring fully drawn collars in 2 through 14 FPI spacing, the fins are self spacing and mechanically bonded to the tubes. This design was heavily influenced by those used in ARI listed coils with changes to suit low temperature conditions. Variable fin spacing is available in multiples of the widest spacing (i.e., 1.5/3/6 or 2/4/8). These coils are available in copper or aluminum tube versions for halocarbon refrigerants or aluminum tube for ammonia refrigerant. Coils are also available with a corrosion resistant coating for use in harsh environments.

Motors

Direct drive AMCA rated axial fans are provided. All fans and motors are modular and can be interchanged between unit sizes. OSHA style fan guards are on all models. Motors are ball bearing, TEAO. Standard electrical is 230/460VAC-3PH-60HZ.

Drain Pan

Rapid removal of condensate is accomplished by the use of a full sized (mounted as standard) drain pan. Drain pans can be insulated when required.

Hot Gas Coils

All models are available with hot gas defrost applications. The hot gas coil is provided with a check valve between the hot gas pan coil and the inlet to the evaporator coil as standard.

* Electric Defrost units not UL recognized

Top


Series -SC- Product Coolers

• Superfin™ Construction
• Hot Gas, Air or Electric Defrost **
• UL Recognized
• CRN Recognized

Cabinets

Attractive cabinets are constructed of heavy gauge galvanized sheet metal which virtually eliminates rust and corrosion. galvanized structural supports are provided to prevent panel vibration. units are completely factory assembled and shipped upright ready for field installation. An optional platform mount is available for all models. Brackets are provided on top of all models.

Coils

All units with 7/8" O.D. tube are furnished with MCC's Superfin™ construction. This equilateral pattern, staggered tube design is the ultimate in extended surface heat transfer. Featuring fully drawn collars in 2 through 14 FPI spacing, the fins are self spacing and mechanically bonded to the tubes. This design was heavily influenced by those used in ARI listed coils with changes to suit low temperature conditions. Variable fin spacing is available in multiples of the widest spacing (i.e., 1.5/3/6 or 2/4/8). These coils are available in copper or aluminum tube versions for halocarbon refrigerants or aluminum tube for ammonia refrigerant. Coils are also available with a corrosion resistant coating for use in harsh environments.

Motors

Direct drive AMCA rated axial fans are provided. All fans and motors are modular and can be interchanged between unit sizes. OSHA style fan guards are on all models. Motors are ball bearing, TEAO.

Drain Pan

Rapid removal of condensate is accomplished by the use of a full sized (mounted as standard) drain pan. Drain pans can be insulated when required.

Hot Gas Coils

All models are available with hot gas defrost applications. The hot gas coil is provided with a check valve between the hot gas pan coil and the inlet to the evaporator coil as standard. All hot gas defrost units feature the "No Bridge" crossover system*.
 
* US Patent #5315836
** Electric defrost not UL recognized.

Top