Download
Catalogs
Buyer
Terms and Conditions
- Series
-C- Product Cooler

- •
Superfin™ Construction
- •
Hot Gas, Air or Electric Defrost **
- •
UL Recognized
- •
CRN Recognized
Cabinets
Attractive
cabinets are constructed of heavy gauge galvanized
sheet metal which virtually eliminates rust and
corrosion. galvanized structural supports are
provided to prevent panel vibration. units are
completely factory assembled and shipped upright
ready for field installation. An optional platform
mount is available for all models. Brackets are
provided on top of all models.
Coils
All
units with 7/8" O.D. tube are furnished with
MCC's Superfin™ construction. This equilateral
pattern, staggered tube design is the ultimate in
extended surface heat transfer. Featuring fully
drawn collars in 2 through 14 FPI spacing, the fins
are self spacing and mechanically bonded to the
tubes. This design was heavily influenced by those
used in ARI listed
coils with changes to suit low temperature
conditions. Variable fin spacing is available in
multiples of the widest spacing (i.e., 1.5/3/6 or
2/4/8). These coils are available in copper or
aluminum tube versions for halocarbon refrigerants
or aluminum tube for ammonia refrigerant. Coils are
also available with a corrosion resistant coating
for use in harsh environments.
Motors
Direct
drive AMCA rated axial fans are provided. All fans
and motors are modular and can be interchanged
between unit sizes. OSHA style fan guards are on all
models. Motors are ball bearing, TEAO.
Drain
Pan
Rapid
removal of condensate is accomplished by the use of
a full sized (mounted as standard) drain pan. Drain
pans can be insulated when required.
Hot
Gas Coils
All
models are available with hot gas defrost
applications. The hot gas coil is provided with a
check valve between the hot gas pan coil and the
inlet to the evaporator coil as standard. All hot
gas defrost units feature the "No Bridge"
crossover system*.
- *
US Patent #5315836
- ** Electric defrost
not UL recognized
Top
Series
-CF- Product Coolers
Information Coming Soon.
Top
- Series -D-
Product Coolers
- • Low Velocity
Dual Coils For Coolers
- • High Velocity
Dual Coils For freezers
- • 80 Models
- • Superfin™
Construction
- • 12 to 75 sq.
ft. Face Area
- • 6,300 to 46,500
CFM
- • 3.3 to 32 Tons
(at 10° temp difference)
- • Hot Gas or Air
Defrost
- • UL Recognized
- • CRN Recognized
Cabinets
- Modular, heavy duty, mill
galvanized, sheet steel construction to eliminate
rust and corrosion. Panels are formed with
strategically placed flanges to prevent excessive
panel flutter. Hangers are bolted to internal
structural pieces to ensure total support of the
unit. Units are shipped completely factory assembled
in the upright position and are ready for rigging.
Expansion
Valves
- All direct expansion
coils are available with factory selected and
mounted thermal expansion valves.
Coils
- All units with
7/8" O.D. tube are furnished with MCC's "Superfin™"
construction. This equilateral pattern, staggered
tube design is the ultimate in extended surface heat
transfer. Featuring fully drawn collars in 2 through
14 FPI spacing, the fins are self spacing and
mechanically bonded to the tubes. This design was
heavily influenced by those used in ARI listed coils
with changes to suit low temperature conditions.
Variable fin spacing is available in multiples of
the widest spacing (i.e., 1.5/3/6 or 2/4/8). These
coils are available in copper or aluminum tube
versions for halocarbon refrigerants or aluminum
tube for ammonia refrigerant. Coils are also
available with a corrosion resistant coating for use
in harsh environments.
Motors
- All motors are totally
enclosed to minimize the possibility of winding
contamination from moisture and airborne materials.
All motors are mounted on a galvanized formed steel
plate base. 50HZ motors are available for all
applications. All Motors are prewired to a junction
box.
Fans
- Direct drive axial
fans are a heavy duty industrial design All are mill
galvanized steel construction for corrosion
resistance. All fans are shrouded by a computer
designed volute for maximum efficiency. All fans are
compartmentalized.
Drain Pan
- Rapid removal of
condensate is accomplished by the use of sloped
drain pans. The pans can be furnished with an
insulated bottoms where required Insulated pans are
suggested when using hot gas defrost and/or when the
unit is located in an area with high humidity.
Hot Gas
Coils
- All models are
available with hot gas defrost. The hot gas pan
coils are furnished with a mounted and prepiped
check valve between the pan coils and the evaporator
coils as standard. Units with hot gas defrost in the
coil only do not have the pan coil and check valve
(the defrost piping is external to the unit and done
by others). All hot gas defrost units feature the
"no bridge" crossover system*
* US Patent
#5315836
Top
- Series -L-
Unit Coolers
- • 54 Models
- • Superfin™
Construction
- • 5,326 to
10,652 CFM
- • 3.0 to 10.6
tons (at 10° temp difference)
- • Hot Gas, Air
or Electric Defrost
- • UL Recognized
- • CRN
Recognized
Cabinets
- Attractive cabinets
are constructed of heavy gauge galvanized sheet
metal which virtually eliminates rust and corrosion.
galvanized structurals supports are provided to
prevent panel vibration. units are completely
factory assembled and shipped upright ready for
field installation. An optional platform mount is
available for all models. Brackets are provided on
top of all models.
Coils
- All units with
7/8" O.D. tube are furnished with MCC's
Superfin™ construction. This equilateral pattern,
staggered tube design is the ultimate in extended
surface heat transfer. Featuring fully drawn collars
in 2 through 14 FPI spacing, the fins are self
spacing and mechanically bonded to the tubes. This
design was heavily influenced by those used in ARI
listed coils with changes to suit low temperature
conditions. Variable fin spacing is available in
multiples of the widest spacing (i.e., 1.5/3/6 or
2/4/8). These coils are available in copper or
aluminum tube versions for halocarbon refrigerants
or aluminum tube for ammonia refrigerant. Coils are
also available with a corrosion resistant coating
for use in harsh environments.
Motors
- Direct drive AMCA
rated axial fans are provided. All fans and motors
are modular and can be interchanged between unit
sizes. OSHA style fan guards are on all models.
Motors are ball bearing, TEAO.
Drain Pan
- Rapid removal of
condensate is accomplished by the use of a full
sized (mounted as standard) drain pan. Drain pans
can be insulated when required.
Hot Gas
Coils
- All models are
available with hot gas defrost applications. The hot
gas coil is provided with a check valve between the
hot gas pan coil and the inlet to the evaporator
coil as standard. All hot gas defrost units feature
the "No Bridge" crossover system*.
* US Patent
#5315836
- Series -M-
Product Coolers
- • Superfin™
Construction
- • 8 to 117 sq.
ft. Face Are
- • 4,600 to
117,000 CFM
- • 1.7 to 91.3
Tons (at 10° temp difference)
- • Hot Gas, Air,
Water or Electric Defrost
- • UL Recognized
- • CRN
Recognized
Construction
Coils
- All units with
7/8" O.D. tube are furnished with MCC's
Superfin™ construction. This equilateral pattern,
staggered tube design is the ultimate in extended
surface heat transfer. Featuring fully drawn collars
in 2 through 14 FPI spacing, the fins are self
spacing and mechanically bonded to the tubes. This
design was heavily influenced by those used in ARI
listed coils with changes to suit low temperature
conditions. Variable fin spacing is available in
multiples of the widest spacing (i.e., 1.5/3/6 or
2/4/8). These coils are available in copper or
aluminum tube versions for halocarbon refrigerants
or aluminum tube for ammonia refrigerant. Coils are
also available with a corrosion resistant coating
for use in harsh environments.
Cabinets
- Modular, heavy duty,
mill galvanized, sheet steel construction to
eliminate rust and corrosion. Panels are formed with
strategically placed flanges to prevent excessive
panel flutter. Hangers are bolted to internal
structural pieces to ensure total support of the
unit. Units are shipped completely factory assembled
in the upright position and are ready for rigging.
Expansion
Valves
- All direct expansion
coils are available with factory selected and
mounted thermal expansion valves.
Drain Pan
- Rapid removal of
condensate is accomplished by the use of a full
sized (mounted as standard) drain pan. Drain pans
can be insulated when required.
Motors
- All motors are totally
enclosed to minimize the possibility of winding
contamination from moisture and airborne materials.
All motors are mounted on a galvanized formed steel
bases. The modular design of this assembly allows
limited changes in horsepower/RPM/fan combinations
within the parameters of the M Series catalogue. 50
HZ motors are available for all applications. All
Motors are prewired to junction boxes.
Fans
- Direct drive axial
fans are a heavy duty industrial design All are mill
galvanized steel construction for corrosion
resistance. Cast aluminum fans are available for
specific applications. All fans are shrouded by a
computer designed volute for maximum efficiency. All
fans are compartmentalized.
Hot Gas Pan
Coils
- All models are
available with hot gas defrost. The hot gas pan coil
is furnished with a mounted and prepiped check valve
between the pan coil and the evaporator coil as
standard. Units with hot gas defrost in the coil
only do not have the pan coil and check valve (the
defrost piping is external to the unit and done by
others). All hot gas defrost units feature the
"no bridge" crossover system*.
Electric
Defrost
- Electric defrost** is
available on all units. The defrost heater elements
are low watt density, large diameter stainless steel
sheathed elements inserted directly into the coil
fins. The fins have a drawn collar similar to the
tube hole. The heaters are held in place by a clip
to prevent them from creeping. The heaters have
molded silicone rubber leads and are UL listed. All
wiring is terminated in a junction box including a
termination 'stat for easy field connection.
* US Patent #5315836
** Electric Defrost
units not UL recognized
Optional
Features
45° Fan
Turndowns
- Constructed of heavy
gauge galvanized sheet and mounted to the front of
the unit cabinet, these help direct the air for
certain types of blast freezing operations.
90° Fan
Turndowns
- Constructed of heavy
gauge galvanized sheet and mounted to the front of
the unit cabinet, these allow the standard
evaporator to be used in penthouse applications.
Extended
Legs
- Constructed of
structural steel (hot dipped galvanized) and heavy
gauge galvanized sheet, these raise the evaporator
for penthouse applications and certain other
platform mounted requirements.
Motors
- Two speed, high
efficiency, or exposion proof motors are available
on all unit sizes.
Long Throw
Nozzles
- Tapered long throw
nozzles are available to enhance the air flow. The
units with 26" fans normally throw
approximately 80', 36" fans approximately 115'
and 42" fans approximately 140'. The addition
of the long throw nozzle adds an estimated 30% to
the throw.
Top
- Series -R-
Rail Riders
- • Superfin™
Construction
- • 48 Models
- • 5.9 to 27.5
Tons (at 10° temperature difference)
- • Hot Gas, Air
or Electric Defrost*
- • UL Recognized
- • CRN
Recognized
Cabinets
- Attractive cabinets are
constructed of heavy gauge galvanized sheet metal
which vertually eliminates rust and corrosion.
galvanized structurals supports are provided to
prevent panel vibration. units are completely
factory assembled and shipped upright ready for
field installation.
Coils
- All units with 7/8" O.D.
tube are furnished with MCC's Superfin™
construction. This equilateral pattern, staggered
tube design is the ultimate in extended surface heat
transfer. Featuring fully drawn collars in 2 through
14 FPI spacing, the fins are self spacing and
mechanically bonded to the tubes. This design was
heavily influenced by those used in ARI listed coils
with changes to suit low temperature conditions.
Variable fin spacing is available in multiples of
the widest spacing (i.e., 1.5/3/6 or 2/4/8). These
coils are available in copper or aluminum tube
versions for halocarbon refrigerants or aluminum
tube for ammonia refrigerant. Coils are also
available with a corrosion resistant coating for use
in harsh environments.
Motors
- Direct drive AMCA rated axial
fans are provided. All fans and motors are modular
and can be interchanged between unit sizes. OSHA
style fan guards are on all models. Motors are ball
bearing, TEAO. Standard electrical is
230/460VAC-3PH-60HZ.
Drain Pan
- Rapid removal of condensate is
accomplished by the use of a full sized (mounted as
standard) drain pan. Drain pans can be insulated
when required.
Hot Gas Coils
- All models are available with
hot gas defrost applications. The hot gas coil is
provided with a check valve between the hot gas pan
coil and the inlet to the evaporator coil as
standard.
* Electric
Defrost units not UL recognized
Top
Series -SC-
Product Coolers

- • Superfin™
Construction
- • Hot Gas, Air
or Electric Defrost **
- • UL Recognized
- • CRN
Recognized
Cabinets
- Attractive cabinets
are constructed of heavy gauge galvanized sheet
metal which virtually eliminates rust and corrosion.
galvanized structural supports are provided to
prevent panel vibration. units are completely
factory assembled and shipped upright ready for
field installation. An optional platform mount is
available for all models. Brackets are provided on
top of all models.
Coils
- All units with
7/8" O.D. tube are furnished with MCC's
Superfin™ construction. This equilateral pattern,
staggered tube design is the ultimate in extended
surface heat transfer. Featuring fully drawn collars
in 2 through 14 FPI spacing, the fins are self
spacing and mechanically bonded to the tubes. This
design was heavily influenced by those used in ARI
listed coils with changes to suit low temperature
conditions. Variable fin spacing is available in
multiples of the widest spacing (i.e., 1.5/3/6 or
2/4/8). These coils are available in copper or
aluminum tube versions for halocarbon refrigerants
or aluminum tube for ammonia refrigerant. Coils are
also available with a corrosion resistant coating
for use in harsh environments.
Motors
- Direct drive AMCA
rated axial fans are provided. All fans and motors
are modular and can be interchanged between unit
sizes. OSHA style fan guards are on all models.
Motors are ball bearing, TEAO.
Drain Pan
- Rapid removal of
condensate is accomplished by the use of a full
sized (mounted as standard) drain pan. Drain pans
can be insulated when required.
Hot Gas
Coils
- All models are
available with hot gas defrost applications. The hot
gas coil is provided with a check valve between the
hot gas pan coil and the inlet to the evaporator
coil as standard. All hot gas defrost units feature
the "No Bridge" crossover system*.
* US Patent #5315836
** Electric defrost not
UL recognized.
Top
|